<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Products &#8211; Centrum Scientific Instrument</title>
	<atom:link href="https://www.csi-globe.com/en/products-2/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.csi-globe.com</link>
	<description>Gas detector, indoor air quality, flame detector, emergency button, control system, broadcast intercom system, agent, distribution, Honeywell, MTI</description>
	<lastBuildDate>Wed, 16 Jul 2025 01:34:03 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>

<image>
	<url>https://www.csi-globe.com/wp-content/uploads/2023/12/cropped-IMG_0561-e1702477899453-32x32.webp</url>
	<title>Products &#8211; Centrum Scientific Instrument</title>
	<link>https://www.csi-globe.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GSP Pro Gas Sampling Pump (Stainless Steel)</title>
		<link>https://www.csi-globe.com/en/products-2/gsp-pro-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Tue, 19 Dec 2023 05:47:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3895</guid>

					<description><![CDATA[<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;"><strong><a title="GSP Pro" href="https://www.csi-globe.com/?page_id=3895" target="_blank" rel="noopener"><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">GSP Pro</span></span></a> for </strong></span></span><span style="vertical-align: inherit;"><strong><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener">MTI</a></strong></span> products</h5>
The GSP Pro is an explosion-proof gas sampling pump, which can be matched with 6.35mm O.D. S.S. SMLS tube (0.89mm THK) ; GSP Pro has a dry contact output (Fault)
Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel-Making / Semiconductor etc. hazardous areas
<ul>
 	<li>Relay output (Fault).</li>
 	<li>Use the magnetic bar to adjust the eight-stage torque.</li>
 	<li>The display show power , fault and torque status.</li>
 	<li>CNS approved for hazardous areas use.</li>
 	<li>Low maintenance cost and easy calibration.</li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="GSP Pro" src="https://sketchfab.com/models/47294d3af27c48839a3809864d6841d2/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specifications</h4>
<h5>Output Signals</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Relay:Fault (30VDC/5A or 220VAC/5A)</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Operating  Ambience</span></span></h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">T5：-40~+50°C </span></span><br />
<span style="vertical-align: inherit;"><span style="vertical-align: inherit;">T6：-40~+60°C</span></span><br />
<span style="vertical-align: inherit;"><span style="vertical-align: inherit;">0~95%RH (non condensing)，1 atm±20%</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Display</span></span></h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">LED:Power , fault and torque (eight stage)</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Operating Voltage</span></span></h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power Consumption</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">&lt;40W</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Flowrate</span></span></h5>
<p>1 Liter/min (max)</p>
<h5>Vacuum</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">-50KPa</span></span></p>
<h5>Pressure</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">80KPa</span></span></p>
<h5>Tube size</h5>
<p>6.35mm O.D. S.S. SMLS tube (0.89mm THK)</p>
<h5>Installation</h5>
<p>Wall or pipeline mount</p>
<h5>Enclosure material</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">S.S.316</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Weig</span></span><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">ht</span></span></h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">3.5Kgs</span></span></p>
<h5>Ingress protection</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">IP66</span></span></p>
<h5>Enclosure entries</h5>
<p>2 cable entries 3/4&#8243;NPT</p>
<h5>Features</h5>
<p>Adjustable torque (eight stage)<br />
Automatically restart when blocked<br />
Maintenance through the magnetic wand</p>
<h5>Approvals</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">CNS(ITRI)：Ex db IIC T6/T5 Gb</span></span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ITEL Pro Gas Detector (Stainless Steel)</title>
		<link>https://www.csi-globe.com/en/products-2/itel-pro-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:38:48 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3952</guid>

					<description><![CDATA[<div class="post_title2">
<h5><span style="vertical-align: inherit;"> </span><a title="ITEL Pro" href="https://www.csi-globe.com/?page_id=3952" target="_blank" rel="noopener"><span style="vertical-align: inherit;">ITEL Pro</span></a><span style="vertical-align: inherit;">  for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Combustible/Toxic/VOC

</div>
</div>
</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The ITEL Pro multi-function gas detector is designed for use with sensor cartridge of catalytic , electrochemical , PID or NDIR type . ITEL Pro have 4~20mA , Relay , HART (option) &#38; RS-485 signal output interface.

</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel- Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
</div>
</div>
<ul>
 	<li><span style="vertical-align: inherit;">4~20mA output (3-wire or 4-wire).</span></li>
 	<li><span style="vertical-align: inherit;">4~20mA output mode can select Source , Sink , Isolated.</span></li>
 	<li><span style="vertical-align: inherit;">RS-485 (Modbus RTU) or HART output .</span></li>
 	<li><span style="vertical-align: inherit;">Relay output (A1,A2,Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Display show Gas Name , Range , Value , Alarm (A1,A2&#38;Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Calibration &#38; adjustment use a
magnetic wand.</span></li>
 	<li><span style="vertical-align: inherit;">Use MTI Smart Swappable Module.</span></li>
 	<li><span style="vertical-align: inherit;">Up to 5 points calibration.</span></li>
 	<li><span style="vertical-align: inherit;">Calibration Remind (180 days).</span></li>
 	<li><span style="vertical-align: inherit;">CNS approved for hazardous areas use.</span></li>
 	<li><span style="vertical-align: inherit;">Low maintenance cost &#38; easy
calibration.</span></li>
</ul>
</div>
<div class="sketchfab-embed-wrapper"><iframe title="ITEL Pro" src="https://sketchfab.com/models/136de54fad354b4b8dd22703ef8f5197/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Output signals</h5>
<p>Analogue : 4~20mA (3-wire or 4-wire)<br />
Digital : RS-485 (Modbus RTU) or HART [Ver.7]<br />
Relay : Fault/A1/A2 (30VDC/5A or 250VAC/5A)</p>
<h5>Operating temperature</h5>
<p>T6 : -40~+55°C<br />
T5 : -40~+65°C<br />
T4 : -40~+75°C</p>
<h5>Operating relative</h5>
<p>0~95%RH (non condensing)，1 atm±20%</p>
<h5>Local Display</h5>
<p>2 rows , 4 digital characters , 20 x 7 dot-matrix display</p>
<h5>Display range</h5>
<p>0~9999</p>
<h5>Unit</h5>
<p>%LEL、%VOL、ppm、mg/m3</p>
<h5>Operating voltage</h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt; 6W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<p>S.S.316</p>
<h5>Weight</h5>
<p>3.8Kg</p>
<h5>Ingress protection</h5>
<p>IP66</p>
<h5>Feature</h5>
<p>Adjust Alarm value, Alarm latching &amp; action method<br />
Self-test indication<br />
4~20mA output test &amp; Relay test<br />
4、8、12、16、20mA output value adjusted<br />
Password protection<br />
5 point calibration (Zero&amp;Span, 2 points, 3 points, 4 points or 5 points)</p>
<h5>Approvals</h5>
<p>CNS(ITRI) : Ex db IIC T6..T4 Gb + Ex tb IIIC T85°C Db</p>
<h5>Test reports</h5>
<p>CE-EMC/RFI : EN 50270 (2015)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ITEL Plus Gas Detector (Aluminum)</title>
		<link>https://www.csi-globe.com/en/products-2/itel-plus-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:36:53 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3955</guid>

					<description><![CDATA[<div class="post_title2">
<h5><a title="ITEL Plus" href="https://www.csi-globe.com/?page_id=3955" target="_blank" rel="noopener">ITEL Plus</a> <span style="vertical-align: inherit;">for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
Combustible/Toxic/VOC

The ITEL Plus multi-function gas detector is designed for use with sensor cartridge of catalytic , electrochemical , PID or NDIR type . ITEL Plus have 4~20mA , Relay , HART (option) &#38; RS-485 signal output interface.
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel- Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
</div>
</div>
<ul>
 	<li><span style="vertical-align: inherit;">4~20mA output (3-wire or 4-wire).</span></li>
 	<li><span style="vertical-align: inherit;">4~20mA output mode can select Source , Sink , Isolated.</span></li>
 	<li><span style="vertical-align: inherit;">RS-485 (Modbus RTU) or HART output .</span></li>
 	<li><span style="vertical-align: inherit;">Relay output (A1,A2,Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Display show Gas Name , Range , Value , Alarm (A1,A2&#38;Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Calibration &#38; adjustment use a magnetic wand.</span></li>
 	<li><span style="vertical-align: inherit;">Use MTI Smart Swappable Module.</span></li>
 	<li><span style="vertical-align: inherit;">Up to 5 points calibration.</span></li>
 	<li><span style="vertical-align: inherit;">Calibration Remind (180 days).</span></li>
 	<li><span style="vertical-align: inherit;">CNS approved for hazardous areas use.</span></li>
 	<li><span style="vertical-align: inherit;">Low maintenance cost &#38; easy calibration.</span></li>
</ul>
</div>
</div>
</div>
</div>
<div class="sketchfab-embed-wrapper"><iframe title="ITEL Plus" src="https://sketchfab.com/models/c5ba77bbfa2d453fbe348ada58fb0269/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Output signals</h5>
<p>Analogue : 4~20mA (3-wire or 4-wire)<br />
Digital : RS-485 (Modbus RTU) or HART [Ver.7]<br />
Relay : Fault/A1/A2 (30VDC/5A or 250VAC/5A)</p>
<h5>Operating temperature</h5>
<p>-40~+85°C</p>
<h5>Operating relative</h5>
<p>0~95%RH (non condensing)，1 atm±20%</p>
<h5>Local Display</h5>
<p>2 rows , 4 digital characters , 20 x 7 dot-matrix display</p>
<h5>Display range</h5>
<p>0~9999</p>
<h5>Unit</h5>
<p>%LEL、%VOL、ppm、mg/m3</p>
<h5>Operatingvoltage</h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt; 6W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Transmitter housing : Aluminum alloy</p>
</div>
</div>
</div>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Sensor housing : S.S.316</p>
</div>
</div>
</div>
<h5>Weight</h5>
<p>2.2Kg</p>
<h5>Ingress protection</h5>
<p>IP66</p>
<h5>Feature</h5>
<p>Adjust Alarm value, Alarm latching &amp; action method<br />
Self-test indication<br />
4~20mA output test &amp; Relay test<br />
4、8、12、16、20mA output value adjusted<br />
Password protection<br />
5 point calibration (Zero&amp;Span, 2 points, 3 points, 4 points or 5 points)</p>
<h5>Approvals</h5>
<p>CNS : Ex db IIC T6 Gb X + Ex tb IIIC T85°C Db X</p>
<h5>Test reports</h5>
<p>CE-EMC/RFI : EN 50270 (2015)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>ITEL Gas Detector</title>
		<link>https://www.csi-globe.com/en/products-2/itel-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:31:06 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3956</guid>

					<description><![CDATA[<h5><a title="ITEL" href="https://www.csi-globe.com/?page_id=3956" target="_blank" rel="noopener">ITEL</a> <span style="vertical-align: inherit;">for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
Combustible/Toxic/VOC
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The ITEL multi gas detector is designed for use with gas sensor of catalytic , electrochemical , PID or NDIR sensor cartridge. ITEL have 4~20mA , Relay , HART(option) &#38; RS-485 signal output interface.

</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel-Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
<ul>
 	<li>4~20mA output (3-wire or 4-wire).</li>
 	<li>RS-485 (Modbus RTU) or HART output.</li>
 	<li>Relay output (A1,A2,Fault).</li>
 	<li>Calibration and adjustment use a magnetic wand.</li>
 	<li>Display are shown the gas name , range , reading and alarm(A1,A2,Fault).</li>
 	<li>UL/CNS/CPA approved for hazardous areas use.</li>
 	<li>CE approved for RFI/EMC protection.</li>
 	<li>CE approved for EFT/Burst Immunity.</li>
 	<li>Low maintenance cost and easy calibration.</li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="ITEL" src="https://sketchfab.com/models/6cc19e225e4e4797a3b4436a120b4537/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Principle</h5>
<p>Catalytic / Electrochemical / PID / NDIR</p>
<h5>Output signals</h5>
<p>Analogue : 4~20mA (3-wire or 4-wire)<br />
Digital : RS-485 (Modbus RTU) or HART [Ver.7]<br />
Relay : Fault/A1/A2 (30VDC &amp; 2A)</p>
<h5>Operating temperature</h5>
<p>Standard : -20~+60°C<br />
High : -40~+85°C (option)</p>
<h5>Operating conditions</h5>
<p>0~99%RH , 100%RH (non condensing) , 1 atm±20%</p>
<h5>Local Display</h5>
<p>LED : 2 rows , 4 digital characters, 20 x 7 dot-matrix display<br />
LCD : back-lit biserial display<br />
Tricolor LCD : back-lit biserial display (Normal : Green / Alarm : Red / Fault : yellow)</p>
<h5>Display range</h5>
<p>0~100%LEL / 0~100%VOL / 0~9999ppm / 0~9999mg/m3 (can be set by user)</p>
<h5>Operating voltage</h5>
<p>24VDC normal (18~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt; 6W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Transmitter housing : Aluminum alloy or S.S.316</p>
</div>
</div>
</div>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Sensor housing : S.S.316</p>
</div>
</div>
</div>
<h5>Weight</h5>
<p>Aluminum alloy : 2.2kg ; S.S.316 : 6.5kg</p>
<h5>Ingress protection</h5>
<p>IP 66 with corrosion-resistant ; NEMA 4X</p>
<h5>Feature</h5>
<p>Adjustable alarm settings<br />
Latching / Non-Latching alarms<br />
Self-test indication<br />
Simulation / Calibration 4-20mA output<br />
Password protected</p>
<h5>Approvals (Aluminum alloy only)</h5>
<p>UL : Class I , Division 1 , Groups B , C &amp; D<br />
Class II , Division 1 , Groups E , F &amp; G ; NEMA 4X<br />
CPA (China)</p>
<h5>Approvals</h5>
<p>CNS(ITRI) : Ex d IIC T6 Gb + Ex tb IIIC T85°C Db</p>
<h5>Test reports</h5>
<p>EMC/RFI CE : EN61000-6 -2/-4<br />
EN 50270<br />
EFT/Burst Immunity CE : EN61000-4 -4</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>6000-KD Pro Combustible Gas Detector(Stainless Steel)</title>
		<link>https://www.csi-globe.com/en/products-2/6000-kd-pro-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:29:36 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3958</guid>

					<description><![CDATA[<h5><a title="6000-KD Pro" href="https://www.csi-globe.com/?page_id=3958" target="_blank" rel="noopener"><span style="vertical-align: inherit;">6000-KD Pro</span></a><span style="vertical-align: inherit;">  for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Combustible

</div>
</div>
</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The 6000-KD Pro Combustible gas detector is designed for use with sensor cartridge of catalytic , electrochemical , PID or NDIR type . 6000-KD Pro have 4~20mA , Relay , HART (option) &#38; RS-485 signal output interface.

</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel- Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
</div>
</div>
<ul>
 	<li><span style="vertical-align: inherit;">4~20mA output (3-wire or 4-wire).</span></li>
 	<li><span style="vertical-align: inherit;">4~20mA output mode can select Source , Sink , Isolated.</span></li>
 	<li><span style="vertical-align: inherit;">RS-485 (Modbus RTU) or HART output .</span></li>
 	<li><span style="vertical-align: inherit;">Relay output (A1,A2,Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Alarm (A1,A2&#38;Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Calibration &#38; adjustment use a magnetic wand.</span></li>
 	<li><span style="vertical-align: inherit;">Use MTI Smart Swappable Module.</span></li>
 	<li><span style="vertical-align: inherit;">Up to 5 points calibration.</span></li>
 	<li><span style="vertical-align: inherit;">Calibration Remind (180 days).</span></li>
 	<li><span style="vertical-align: inherit;">CNS approved for hazardous areas use.</span></li>
 	<li><span style="vertical-align: inherit;">Low maintenance cost &#38; easy calibration.</span></li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="6000 KD Pro" src="https://sketchfab.com/models/ea0a838588d04abc8994f7bb41f079f6/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Output signals</h5>
<p>Analogue : 4~20mA (3-wire or 4-wire)<br />
Digital : RS-485 (Modbus RTU) or HART [Ver.7]<br />
Relay : Fault/A1/A2 (30VDC/5A or 250VAC/5A)</p>
<h5>Operating temperature</h5>
<p>T6 : -40~+55°C<br />
T5 : -40~+65°C<br />
T4 : -40~+75°C</p>
<h5>Operating relative</h5>
<p>0~95%RH (non condensing)，1 atm±20%</p>
<h5>Local Display</h5>
<p>4 digital characters</p>
<h5>Display range</h5>
<p>0~9999</p>
<h5>Unit</h5>
<p>%LEL、%VOL、ppm、mg/m3</p>
<h5>Operating voltage</h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt; 6W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<p>S.S.316</p>
<h5>Weight</h5>
<p>3.8Kg</p>
<h5>Ingress protection</h5>
<p>IP66</p>
<h5>Feature</h5>
<p>Adjust Alarm value, Alarm latching &amp; action method<br />
Self-test indication<br />
4~20mA output test &amp; Relay test<br />
4、8、12、16、20mA output value adjusted<br />
Password protection<br />
5 point calibration (Zero&amp;Span, 2 points, 3 points, 4 points or 5 points)</p>
<h5>Approvals</h5>
<p>CNS(ITRI) : Ex db IIC T6..T4 Gb + Ex tb IIIC T85°C Db</p>
<h5>Test reports</h5>
<p>CE-EMC/RFI : EN 50270 (2015)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>6000-KD Plus Combustible Gas Detector(Aluminum)</title>
		<link>https://www.csi-globe.com/en/products-2/6000-kd-plus-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:28:37 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3959</guid>

					<description><![CDATA[<h5><a title="6000-KD Plus" href="https://www.csi-globe.com/?page_id=3959" target="_blank" rel="noopener"><span style="vertical-align: inherit;">6000-KD Plus</span></a><span style="vertical-align: inherit;">  for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Combustible

</div>
</div>
</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The 6000-KD Plus Combustible gas detector is designed for use with sensor cartridge of catalytic , electrochemical , PID or NDIR type . 6000-KD Plus have 4~20mA , Relay , HART (option) &#38; RS-485 signal output interface.

</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel- Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
</div>
</div>
<ul>
 	<li><span style="vertical-align: inherit;">4~20mA output (3-wire or 4-wire).</span></li>
 	<li><span style="vertical-align: inherit;">4~20mA output mode can select Source , Sink , Isolated.</span></li>
 	<li><span style="vertical-align: inherit;">RS-485 (Modbus RTU) or HART output .</span></li>
 	<li><span style="vertical-align: inherit;">Relay output (A1,A2,Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Alarm (A1,A2&#38;Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Calibration &#38; adjustment use a magnetic wand.</span></li>
 	<li><span style="vertical-align: inherit;">Use MTI Smart Swappable Module.</span></li>
 	<li><span style="vertical-align: inherit;">Up to 5 points calibration.</span></li>
 	<li><span style="vertical-align: inherit;">Calibration Remind (180 days).</span></li>
 	<li><span style="vertical-align: inherit;">CNS approved for hazardous areas use.</span></li>
 	<li><span style="vertical-align: inherit;">Low maintenance cost &#38; easy calibration.</span></li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="6000 KD Plus" src="https://sketchfab.com/models/36c5957943ff4f2ebcfad5b7122431e8/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Output signals</h5>
<p>Analogue : 4~20mA (3-wire or 4-wire)<br />
Digital : RS-485 (Modbus RTU) or HART [Ver.7]<br />
Relay : Fault/A1/A2 (30VDC/5A or 250VAC/5A)</p>
<h5>Operating temperature</h5>
<p>-40~+85°C</p>
<h5>Operating relative</h5>
<p>0~95%RH (non condensing)，1 atm±20%</p>
<h5>Local Display</h5>
<p>4 digital characters</p>
<h5>Display range</h5>
<p>0~9999</p>
<h5>Operating voltage</h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt; 6W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Transmitter housing : Aluminum alloy</p>
</div>
</div>
</div>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Sensor housing : S.S.316</p>
</div>
</div>
</div>
<h5>Weight</h5>
<p>2.2Kg</p>
<h5>Ingress protection</h5>
<p>IP66</p>
<h5>Feature</h5>
<p>Adjust Alarm value, Alarm latching &amp; action method<br />
Self-test indication<br />
4~20mA output test &amp; Relay test<br />
4、8、12、16、20mA output value adjusted<br />
Password protection<br />
5 point calibration (Zero&amp;Span, 2 points, 3 points, 4 points or 5 points)</p>
<h5>Approvals</h5>
<p>CNS : Ex db IIC T6 Gb X + Ex tb IIIC T85°C Db X</p>
<h5>Test reports</h5>
<p>CE-EMC/RFI : EN 50270 (2015)</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>6000-KD Combustible Gas Detector</title>
		<link>https://www.csi-globe.com/en/products-2/6000-kd-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:27:57 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3960</guid>

					<description><![CDATA[<h5><a title="6000-KD" href="https://www.csi-globe.com/?page_id=3960" target="_blank" rel="noopener">6000-KD</a> <span style="vertical-align: inherit;">for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
Combustible
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The 6000-KD Combustible gas detector is designed for use with gas sensor of catalytic , electrochemical , PID or NDIR sensor cartridge. 6000-KD have 4~20mA , Relay , HART(option) &#38; RS-485 signal output interface.

</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel-Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
<ul>
 	<li>4~20mA output (3-wire or 4-wire).</li>
 	<li>RS-485 (Modbus RTU) and relay output.</li>
 	<li>HART output (option).</li>
 	<li>Calibration and adjustment use a magnetic wand.</li>
 	<li>CNS/CPA approved for hazardous areas use.</li>
 	<li>CE approved for RFI/EMC protection.</li>
 	<li>CE approved for EFT/Burst Immunity.</li>
 	<li>Low maintenance cost and easy calibration.</li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="6000 KD" src="https://sketchfab.com/models/d86c76cfaf5d4624b491b630341bd99f/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Principle</h5>
<p>Catalytic</p>
<h5>Output signals</h5>
<p>Analogue : 4~20mA (3-wire or 4-wire)<br />
Digital : RS-485 (Modbus RTU) or HART [Ver.7]<br />
Relay : Fault/A1/A2 (30VDC &amp; 2A)</p>
<h5>Operating temperature</h5>
<p>Standard : -20~+60°C<br />
High : -40~+85°C (option)</p>
<h5>Operating conditions</h5>
<p>0~99%RH , 100%RH (non condensing) , 1 atm±20%</p>
<h5>Local Display</h5>
<p>LED : 4 digital characters LED display<br />
LCD : back-lit biserial display<br />
Tricolor LCD : back-lit biserial display (Normal : Green / Alarm : Red / Fault : yellow)</p>
<h5>Display range</h5>
<p>LED : 0~100%LEL<br />
LCD : 0~100%LEL / 0~9999ppm</p>
<h5>Operating voltage</h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt; 6W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Transmitter housing : Aluminum alloy or S.S.316</p>
</div>
</div>
</div>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Sensor housing : S.S.316</p>
</div>
</div>
</div>
<h5>Weight</h5>
<p>Aluminum alloy : 2.2kg ; S.S.316 : 6.5kg</p>
<h5>Ingress protection</h5>
<p>IP 66 with corrosion-resistant</p>
<h5>Feature</h5>
<p>Adjustable alarm settings<br />
Latching / Non-Latching alarms<br />
Self-test indication<br />
One-Man calibration</p>
<h5>Approvals (Aluminum alloy only)</h5>
<p>CNS : Ex d IIC T6 Gb + Ex tb IIIC T85°C Db<br />
CPA (China)</p>
<h5>Approvals</h5>
<p>EMC/RFI CE : EN61000-6 -2/-4<br />
EN 50270<br />
EFT/Burst Immunity CE : EN61000-4 -4</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>6000-KN Combustible Gas Detector</title>
		<link>https://www.csi-globe.com/en/products-2/6000-kn-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:26:11 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3961</guid>

					<description><![CDATA[<h5><a title="6000-KN" href="https://www.csi-globe.com/?page_id=3961" target="_blank" rel="noopener">6000-KN</a> <span style="vertical-align: inherit;">for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
Combustible
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The 6000-KN combustible gas detector is designed for use with catalytic sensor , featuring 4~20mA , HART (option) or mV output (option) .

</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel-Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<ul>
 	<li>4~20mA output (3-wire or 4-wire).</li>
 	<li>HART output (option).</li>
 	<li>mV output (option).</li>
 	<li>CNS/CPA approved for hazardous areas use.</li>
 	<li>CE approved for RFI/EMC protection.</li>
 	<li>CE approved for EFT/Burst Immunity.</li>
 	<li>Low maintenance cost and easy calibration.</li>
</ul>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Principle</h5>
<p>Catalytic</p>
<h5>Output signals</h5>
<p>4~20mA , 4~20mA (HART) or mV</p>
<h5>Operating conditions</h5>
<p>Standard : -20~+60°C, 0~99%RH , 100%RH (non condensing), 1 atm±20%</p>
<h5>Display range</h5>
<p>0~100%LEL</p>
<h5>Operating voltage</h5>
<p>4~20mA &amp; HART : 24VDC normal (12~32VDC)<br />
mV : 5VDC normal</p>
<h5>Operating current</h5>
<p>mV : 200mA</p>
<h5>Power consumption</h5>
<p>&lt; 3W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 2">
<div class="section">
<div class="layoutArea">
<div class="column">
<p>Transmitter : Aluminum alloy ; Sensor : S.S.316</p>
</div>
</div>
</div>
</div>
</div>
</div>
</div>
<h5>Weight</h5>
<p>2.16kg</p>
<h5>Ingress protection</h5>
<p>IP 66 with corrosion-resistant</p>
<h5>Feature</h5>
<p>Over-current protection<br />
Self-test indication</p>
<h5>Approvals</h5>
<p>CNS : Ex d IIC T6 Gb<br />
CPA (China)<br />
CE : EN61000-6 -2/-4<br />
EFT/Burst Immunity CE : EN61000-4 -4</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>7000 Pro Toxic Gas Getector (Stainless Steel)</title>
		<link>https://www.csi-globe.com/en/products-2/7000-pro-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:25:27 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3963</guid>

					<description><![CDATA[<h5><a title="7000 Pro" href="https://www.csi-globe.com/?page_id=3963" target="_blank" rel="noopener"><span style="vertical-align: inherit;">7000 Pro</span></a><span style="vertical-align: inherit;">  for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Toxic

</div>
</div>
</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The 7000 Pro Toxic gas detector is designed for use with sensor cartridge of electrochemical , PID or NDIR type . 7000 Pro have 4~20mA , Relay , HART (option) &#38; RS-485 signal output interface.

</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel- Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
</div>
</div>
<ul>
 	<li><span style="vertical-align: inherit;">4~20mA output (3-wire or 4-wire).</span></li>
 	<li><span style="vertical-align: inherit;">4~20mA output mode can select Source , Sink , Isolated.</span></li>
 	<li><span style="vertical-align: inherit;">RS-485 (Modbus RTU) or HART output .</span></li>
 	<li><span style="vertical-align: inherit;">Relay output (A1,A2,Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Alarm (A1,A2&#38;Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Calibration &#38; adjustment use a magnetic wand.</span></li>
 	<li><span style="vertical-align: inherit;">Use MTI Smart Swappable Module.</span></li>
 	<li><span style="vertical-align: inherit;">Up to 5 points calibration.</span></li>
 	<li><span style="vertical-align: inherit;">Calibration Remind (180 days).</span></li>
 	<li><span style="vertical-align: inherit;">CNS approved for hazardous areas use.</span></li>
 	<li><span style="vertical-align: inherit;">Low maintenance cost &#38; easy calibration.</span></li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="7000 Pro" src="https://sketchfab.com/models/6c7b9bdd01c5404bb63898f81a631506/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<div class="post_title2">
<h4>Specification</h4>
<h5>Output signals</h5>
<p>Analogue : 4~20mA (3-wire or 4-wire)<br />
Digital : RS-485 (Modbus RTU) or HART [Ver.7]<br />
Relay : Fault/A1/A2 (30VDC/5A or 250VAC/5A)</p>
<h5>Operating temperature</h5>
<p>T6 : -40~+55°C<br />
T5 : -40~+65°C<br />
T4 : -40~+75°C</p>
<h5>Operating relative</h5>
<p>0~95%RH (non condensing)，1 atm±20%</p>
<h5>Local Display</h5>
<p>4 digital characters</p>
<h5>Display range</h5>
<p>0~9999</p>
<h5>Unit</h5>
<p>%VOL、ppm、mg/m3</p>
<h5>Operating voltage</h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt; 6W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<p>S.S.316</p>
<h5>Weight</h5>
<p>3.8Kg</p>
<h5>Ingress protection</h5>
<p>IP66</p>
<h5>Feature</h5>
<p>Adjust Alarm value, Alarm latching &amp; action method<br />
Self-test indication<br />
4~20mA output test &amp; Relay test<br />
4、8、12、16、20mA output value adjusted<br />
Password protection<br />
5 point calibration (Zero&amp;Span, 2 points, 3 points, 4 points or 5 points)</p>
<h5>Approvals</h5>
<p>CNS(ITRI) : Ex db IIC T6..T4 Gb + Ex tb IIIC T85°C Db</p>
<h5>Test reports</h5>
<p>CE-EMC/RFI : EN 50270 (2015)</p>
</div>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>7000 Plus Toxic Gas Detector (Aluminum)</title>
		<link>https://www.csi-globe.com/en/products-2/7000-plus-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 05:24:18 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3964</guid>

					<description><![CDATA[<h5><a title="7000 Plus" href="https://www.csi-globe.com/?page_id=3964" target="_blank" rel="noopener"><span style="vertical-align: inherit;">7000 Plus</span></a><span style="vertical-align: inherit;">  for </span><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener"><span style="vertical-align: inherit;">MTI</span></a><span style="vertical-align: inherit;"> Product</span></h5>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Toxic

</div>
</div>
</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The 7000 Plus Toxic gas detector is designed for use with sensor cartridge of catalytic , electrochemical , PID or NDIR type . 7000 Plus have 4~20mA , Relay , HART (option) &#38; RS-485 signal output interface.

</div>
</div>
</div>
</div>
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">
<div class="page" title="Page 1">
<div class="layoutArea">
<div class="column">

Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel- Making / Semiconductor etc. hazardous areas

</div>
</div>
</div>
</div>
</div>
</div>
<ul>
 	<li><span style="vertical-align: inherit;">4~20mA output (3-wire or 4-wire).</span></li>
 	<li><span style="vertical-align: inherit;">4~20mA output mode can select Source , Sink , Isolated.</span></li>
 	<li><span style="vertical-align: inherit;">RS-485 (Modbus RTU) or HART output .</span></li>
 	<li><span style="vertical-align: inherit;">Relay output (A1,A2,Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Alarm (A1,A2&#38;Fault).</span></li>
 	<li><span style="vertical-align: inherit;">Calibration &#38; adjustment use a magnetic wand.</span></li>
 	<li><span style="vertical-align: inherit;">Use MTI Smart Swappable Module.</span></li>
 	<li><span style="vertical-align: inherit;">Up to 5 points calibration.</span></li>
 	<li><span style="vertical-align: inherit;">Calibration Remind (180 days).</span></li>
 	<li><span style="vertical-align: inherit;">CNS approved for hazardous areas use.</span></li>
 	<li><span style="vertical-align: inherit;">Low maintenance cost &#38; easy calibration.</span></li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="7000 Plus" src="https://sketchfab.com/models/b76522e874294ff39351463272bea653/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Output signals</h5>
<p>Analogue : 4~20mA (3-wire or 4-wire)<br />
Digital : RS-485 (Modbus RTU) or HART [Ver.7]<br />
Relay : Fault/A1/A2 (30VDC/5A or 250VAC/5A)</p>
<h5>Operating temperature</h5>
<p>-40~+85°C</p>
<h5>Operating relative</h5>
<p>0~95%RH (non condensing)，1 atm±20%</p>
<h5>Local Display</h5>
<p>4 digital characters</p>
<h5>Display range</h5>
<p>0~9999</p>
<h5>Operating voltage</h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt; 6W</p>
<h5>Installation</h5>
<p>Wall or pipe mounting</p>
<h5>Enclosure material</h5>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Transmitter housing : Aluminum alloy</p>
</div>
</div>
</div>
<div class="page" title="Page 2">
<div class="layoutArea">
<div class="column">
<p>Sensor housing : S.S.316</p>
</div>
</div>
</div>
<h5>Weight</h5>
<p>2.2Kg</p>
<h5>Ingress protection</h5>
<p>IP66</p>
<h5>Feature</h5>
<p>Adjust Alarm value, Alarm latching &amp; action method<br />
Self-test indication<br />
4~20mA output test &amp; Relay test<br />
4、8、12、16、20mA output value adjusted<br />
Password protection<br />
5 point calibration (Zero&amp;Span, 2 points, 3 points, 4 points or 5 points)</p>
<h5>Approvals</h5>
<p>CNS : Ex db IIC T6 Gb X + Ex tb IIIC T85°C Db X</p>
<h5>Test reports</h5>
<p>CE-EMC/RFI : EN 50270 (2015)</p>