<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Gas Sampling Pump &#8211; Centrum Scientific Instrument</title>
	<atom:link href="https://www.csi-globe.com/en/product-tag/gas-sampling-pump-en/feed/" rel="self" type="application/rss+xml" />
	<link>https://www.csi-globe.com</link>
	<description>Gas detector, indoor air quality, flame detector, emergency button, control system, broadcast intercom system, agent, distribution, Honeywell, MTI</description>
	<lastBuildDate>Tue, 19 Aug 2025 05:46:41 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.5</generator>

<image>
	<url>https://www.csi-globe.com/wp-content/uploads/2023/12/cropped-IMG_0561-e1702477899453-32x32.webp</url>
	<title>Gas Sampling Pump &#8211; Centrum Scientific Instrument</title>
	<link>https://www.csi-globe.com</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>GSP Pro Gas Sampling Pump (Stainless Steel)</title>
		<link>https://www.csi-globe.com/en/products-2/gsp-pro-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Tue, 19 Dec 2023 05:47:24 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3895</guid>

					<description><![CDATA[<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;"><strong><a title="GSP Pro" href="https://www.csi-globe.com/?page_id=3895" target="_blank" rel="noopener"><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">GSP Pro</span></span></a> for </strong></span></span><span style="vertical-align: inherit;"><strong><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener">MTI</a></strong></span> products</h5>
The GSP Pro is an explosion-proof gas sampling pump, which can be matched with 6.35mm O.D. S.S. SMLS tube (0.89mm THK) ; GSP Pro has a dry contact output (Fault)
Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel-Making / Semiconductor etc. hazardous areas
<ul>
 	<li>Relay output (Fault).</li>
 	<li>Use the magnetic bar to adjust the eight-stage torque.</li>
 	<li>The display show power , fault and torque status.</li>
 	<li>CNS approved for hazardous areas use.</li>
 	<li>Low maintenance cost and easy calibration.</li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="GSP Pro" src="https://sketchfab.com/models/47294d3af27c48839a3809864d6841d2/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specifications</h4>
<h5>Output Signals</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Relay:Fault (30VDC/5A or 220VAC/5A)</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Operating  Ambience</span></span></h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">T5：-40~+50°C </span></span><br />
<span style="vertical-align: inherit;"><span style="vertical-align: inherit;">T6：-40~+60°C</span></span><br />
<span style="vertical-align: inherit;"><span style="vertical-align: inherit;">0~95%RH (non condensing)，1 atm±20%</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Display</span></span></h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">LED:Power , fault and torque (eight stage)</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Operating Voltage</span></span></h5>
<p>24VDC normal (12~32VDC)</p>
<h5>Power Consumption</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">&lt;40W</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Flowrate</span></span></h5>
<p>1 Liter/min (max)</p>
<h5>Vacuum</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">-50KPa</span></span></p>
<h5>Pressure</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">80KPa</span></span></p>
<h5>Tube size</h5>
<p>6.35mm O.D. S.S. SMLS tube (0.89mm THK)</p>
<h5>Installation</h5>
<p>Wall or pipeline mount</p>
<h5>Enclosure material</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">S.S.316</span></span></p>
<h5><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">Weig</span></span><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">ht</span></span></h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">3.5Kgs</span></span></p>
<h5>Ingress protection</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">IP66</span></span></p>
<h5>Enclosure entries</h5>
<p>2 cable entries 3/4&#8243;NPT</p>
<h5>Features</h5>
<p>Adjustable torque (eight stage)<br />
Automatically restart when blocked<br />
Maintenance through the magnetic wand</p>
<h5>Approvals</h5>
<p><span style="vertical-align: inherit;"><span style="vertical-align: inherit;">CNS(ITRI)：Ex db IIC T6/T5 Gb</span></span></p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>MGSP Gas Sampling Pump</title>
		<link>https://www.csi-globe.com/en/products-2/mgsp-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 03:59:25 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3972</guid>

					<description><![CDATA[<h5><span style="vertical-align: inherit;"><strong><a title="MGSP" href="https://www.csi-globe.com/?page_id=3972" target="_blank" rel="noopener">MGSP</a> for </strong></span><span style="vertical-align: inherit;"><strong><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener">MTI</a></strong></span> products</h5>
The MGSP is micro gas sampling pump, with LED(Power/Fault) and dry contact(Fault), and easy to use to display and signal output by connected with 9500-series gas detector.
Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Electronics / Semiconductor / Steel-making / Parking lot / Office / School / Lab. etc. non-hazardous areas
<ul>
 	<li>Relay output (Fault).</li>
 	<li>LED(Power/Fault).</li>
 	<li>Combined with 9500 gas detector to become sampling gas detector.</li>
 	<li>Low maintenance cost and easy calibration.</li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="MGSP" src="https://sketchfab.com/models/d633eb0d7ef245d79438ab075cef82db/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1&#38;ui_hint=0" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specification</h4>
<h5>Output signals</h5>
<p>Relay : Fault(30VDC/2.0A)</p>
<h5>Operating conditions</h5>
<p>+5~+40°C , 0~99%RH , 100%RH(non condensing) , 1 atm±20%</p>
<h5>Local display</h5>
<p>LED(Green) : Power<br />
LED(Red) : Fault</p>
<h5>Operating voltage</h5>
<p>24VDC normal(18~32VDC)</p>
<h5>Power consumption</h5>
<p>&lt;40W</p>
<h5>Flowrate</h5>
<p>1.0Liter/min</p>
<h5>Vacuum</h5>
<p>400mbar</p>
<h5>Pressure</h5>
<p>0.9bar(g)</p>
<h5>Installation</h5>
<p>Wall or pipeline mount</p>
<h5>Enclosure material</h5>
<p>ABS</p>
<h5>Weight</h5>
<p>0.8Kg</p>
<h5>Ingress protection</h5>
<p>IP66</p>
<h5>Enclosure entries</h5>
<p>2 pipe entries : 5mm<br />
1 cable entry : M20</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>GSP Gas Sampling Pump</title>
		<link>https://www.csi-globe.com/en/products-2/gsp-en/</link>
		
		<dc:creator><![CDATA[TASI]]></dc:creator>
		<pubDate>Thu, 07 Dec 2023 03:57:01 +0000</pubDate>
				<guid isPermaLink="false">https://www.csi-globe.com/?post_type=product&#038;p=3973</guid>

					<description><![CDATA[<h5><span style="vertical-align: inherit;"><strong><a title="GSP" href="https://www.csi-globe.com/?page_id=3973" target="_blank" rel="noopener">GSP</a> for </strong></span><span style="vertical-align: inherit;"><strong><a title="樹" href="https://www.mti-globe.com/" target="_blank" rel="noopener">MTI</a></strong></span> products</h5>
<div class="page" title="Page 1">
<div class="section">
<div class="layoutArea">
<div class="column">

The model GSP is gas sampling pump, with LED(Power/Fault) and dry contact(Fault), and easy to use to display and signal output by connected with gas detector.

</div>
</div>
</div>
</div>
Applications-
Petrochemical / Pharmaceutical / Chemical / Manufacturing / Aerosol Filling / Steel-Making / Semiconductor etc. hazardous areas
<ul>
 	<li>Relay output (Fault).</li>
 	<li>LED(Power/Fault).</li>
 	<li>CNS approved for hazardous areas use.</li>
 	<li>RFI/EMC protection.</li>
 	<li>Low maintenance cost and easy calibration.</li>
</ul>
<div class="sketchfab-embed-wrapper"><iframe title="GSP" src="https://sketchfab.com/models/6d99ea6feea146c9a0d31f2b52bd986e/embed?autospin=1&#38;autostart=1&#38;camera=0&#38;preload=1&#38;transparent=1&#38;ui_hint=0" frameborder="0" allowfullscreen="allowfullscreen"> </iframe></div>]]></description>
										<content:encoded><![CDATA[<h4>Specifications</h4>
<h5>Output Signals</h5>
<p><span style="vertical-align: inherit;">Relay:Fault (30VDC/2A)</span></p>
<h5><span style="vertical-align: inherit;">Operating  conditions</span></h5>
<p><span style="vertical-align: inherit;">+5~+40°C , 0~99%RH </span>, 100%RH(non condensing)  , 1 atm±20%</p>
<h5><span style="vertical-align: inherit;">Local Display</span></h5>
<div class="page" title="Page 2">
<div class="section">
<div class="layoutArea">
<div class="column">LED(Green) : Power<br />
LED(Red) : Fault</div>
</div>
</div>
</div>
<h5><span style="vertical-align: inherit;">Operating Voltage</span></h5>
<p>24VDC normal (18~32VDC)</p>
<h5>Power Consumption</h5>
<p><span style="vertical-align: inherit;">&lt;40W</span></p>
<h5><span style="vertical-align: inherit;">Flowrate</span></h5>
<p>1 Liter/min</p>
<h5>Vacuum</h5>
<p><span style="vertical-align: inherit;">400 mbar</span></p>
<h5>Pressure</h5>
<p><span style="vertical-align: inherit;">0.9 bar(g)</span></p>
<h5>Installation</h5>
<p>Wall or pipeline mount</p>
<h5>Enclosure material</h5>
<div class="page" title="Page 2">
<div class="section">
<div class="layoutArea">
<div class="column">
<p>Aluminum alloy or S.S.316</p>
</div>
</div>
</div>
</div>
<h5><span style="vertical-align: inherit;">Weig</span><span style="vertical-align: inherit;">ht</span></h5>
<p><span style="vertical-align: inherit;">1.66 Kgs</span></p>
<h5>Ingress protection</h5>
<p><span style="vertical-align: inherit;">IP66</span></p>
<h5>Enclosure entries</h5>
<p>2 pipe entries(ID) : 5mm<br />
2 cable entries 3/4&#8243;NPT</p>
<h5>Approvals</h5>
<p><span style="vertical-align: inherit;">CNS：Ex d IIC T6 Gb</span></p>
]]></content:encoded>
					
		
		